4-21
Use the UP and DOWN arrow keys or the numeric keypad to enter
the telemetry level (20-50
(1)
dBmV).
Forward Sweep Insertion Level
This is the level at which the 3ST inserts (transmits) sweep points.
All sweep points are inserted at the same level. Use the edit box to
set the Sweep Insertion Level to an appropriate value (This will
typically be at maximum (+50
(1)
dBmV) to over come test point loss.).
Use the UP and DOWN arrow keys or the numeric keypad to enter
the sweep insertion level (20-50
(1)
dBmV).
Include Audio Carriers
This selection allows the audio carriers to be excluded resulting in a
faster sweep. Use the UP and DOWN arrow keys to include (Yes) or
exclude (No) audio carriers.
Enable or Disable Reverse Sweep
When Reverse Sweep is enabled, both Forward and Reverse sweep-
ing can be performed. Only Forward sweeping is possible when
Reverse Sweep is disabled.
IMPORTANT: Reverse Sweep should be disabled when there are
no 3SR units being used with the Reverse Sweep
option. This will optimize the update rate of the
Forward Sweep. It should also be disabled if you
are using a 3HRV for reverse sweeping.
Select the Frequency of the Reverse Telemetry Carrier
This is the frequency at which 3SR units with the Reverse Sweep
option will transmit telemetry data. Optimally this will be in a
portion of the reverse frequency band with at least 1 MHz free, and
at best case, in the high end of the return band to avoid potential
interference from ingress.
Commenti su questo manuale