Wavetek 3ST Specifiche Pagina 85

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 102
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 84
5-2
This is why it is best to transmit the sweep from the amplifier test
point and measure it in the headend. This ensures that the system is
properly aligned to carry signals in the reverse path.
5.1.3 Interfacing With Different Network Architectures
Single Cable - Split Band Network
The Model 3ST Sweep Transmitter is connected in the headend as
shown in figure 1. The connections are similar to those made for
forward sweep, with the transmitter output connected to the combin-
ing network. The difference is on the input to the 3ST transmitter.
The system signals along with the transmitted signals are tapped off
and coupled together with the reverse signals using a splitter. This
enables the 3ST transmitter to receive both forward and reverse
telemetry and sweep signals.
Figure 1. Single Cable — Split Band Network Reverse Sweep
Configuration With Bi-Directional Test Points.
In the field, systems with bidirectional test points, (forward and
reverse signals both present on the same test point) a summing
network (provided with each reverse sweep option) is used to enable
reception of forward telemetry and sweep, as well as inject reverse
telemetry and sweep. This summing network simplifies the
connection of the field receiver to the test point.
Vedere la pagina 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 101 102

Commenti su questo manuale

Nessun commento