Each location in the list has an associated type and values for the
descriptive parameters. The parameters are shown in the following
table.
Parameter Min Max Default Units
1 Area 15 column alpha numeric field
2 Amp Id 15 column alpha numeric field
3 Power Configuration IN / OUT / THROUGH
4 Feeder Maker Config 1 9 1
5 Trunk Termination NO YES NO
6 Voltage Setting LOW / MID / HIGH
7 Rev Pad -100.0 +100.0 0.0 dB
8 Rev Equalizer -100.0 +100.0 0.0 dB
9 Fwd Pad -100.0 +100.0 0.0 dB
10 Fwd Equalizer -100.0 +100.0 0.0 dB
There are five types of locations associated with a cable system:
Trunk Amp, Headend, Line Extender, Fiber Node, and Field Test.
Some of the parameters do not apply to certain types of locations.
The following table shows which of the parameters in the table
above apply to each of the location types.